Services
Fire engineering at every stage of your project
From the first sketch to an occupied building, here is what we do at each stage and what you receive. Find your stage, then send us your drawings for a fixed-fee proposal.
Six stages
Services by project stage
-
Stage 1
Concept & feasibility
Before the design is fixed
Identify fire safety considerations while site and design options are being developed.
- Concept fire strategy
- Deemed-to-Satisfy departure scan
- Due diligence for acquisitions
- Design optimisation, such as stair, egress and compartment layouts
You receiveConcept fire strategy letter -
Stage 2
Design development
Developing the design
Agree the fire engineering approach with the building surveyor and DFES before detailed analysis begins.
- Fire Engineering Brief (FEB)
- DFES consultation
- CFD smoke modelling
- Evacuation modelling
- Structural fire analysis
You receiveFire Engineering Brief -
Stage 3
Building permit
Documenting for approval
Show that each Performance Solution meets the Performance Requirements, ready for the building surveyor's certificate.
- Fire Engineering Report (FER)
- Responses to building surveyor and DFES comments
- Coordination with fire services and hydraulic engineers
You receiveFire Engineering Report -
Stage 4
Construction
Work on site
Keep the built work aligned with the approved fire engineering.
- Design change assessments
- Site inspections
You receiveConstruction inspection reports -
Stage 5
Handover
At completion
Record the fire safety requirements that need to be handed over with the completed building.
- Final inspection
- Handover summary of fire safety requirements
You receiveHandover summary -
Stage 6
Occupied buildings
In use
Help owners understand and manage the fire safety of existing buildings.
- Fire safety audits
- Change of use assessments
- Upgrade strategies
- Fire safety risk assessments
You receiveAudit report and upgrade strategy
What we do
Our services
Performance Solutions
Fire safety designs tailored to your building, its occupants and its use, giving you flexibility beyond the standard NCC provisions.
When you need thisBCA compliance advice
Clear guidance on the Building Code of Australia’s fire safety requirements, including fire resistance, egress, compartmentation, firefighting equipment, smoke management and alarm systems.
When you need thisFire and smoke modelling
3D CFD modelling that shows how fire and smoke will spread, so your design and smoke management systems work together.
When you need thisEvacuation modelling
Simulations of how people move through your building, so exits, doors and stairs are sized and placed to get everyone out safely.
When you need thisStructural fire engineering
Analysis of how your structure performs in a fire, so it stays standing long enough to protect occupants and firefighters.
When you need thisFire safety audits
Inspections of existing buildings with clear, prioritised recommendations to bring fire safety up to standard.
When you need thisFire risk assessment
Identifying hazards and weak points so you can fix them before something goes wrong.
When you need this
See the modelling we do: Fire and egress modelling
The WA approval process
How a Performance Solution gets approved in WA
DFES's current guidance describes advice during the PBDB / FEB process and a later review of building plans and specifications. The documents and steps required depend on the project and its approval pathway.
- BriefThe project fire engineer prepares a PBDB / FEB in consultation with relevant stakeholders.
- Preliminary adviceDFES Built Environment Branch reviews the brief and may issue a preliminary advice letter for the project.
- AnalysisThe fire engineer completes the assessment methods recorded in the brief, such as calculations or modelling where applicable.
- Plans and reportThe building surveyor provides plans and specifications for review under regulation 18B. DFES may review the FER and supporting documents where applicable; the applicable response process is project-specific.
- CertificationThe building surveyor considers the applicable FES Commissioner's advice and project documentation when assessing the certificate of design compliance.
Read more: FEB vs FER · Working with DFES · What is a Performance Solution?
Typical timeframes
How long things take
Typical turnaround for common deliverables. We confirm the programme for your project in the proposal.
| Deliverable | Measured from | Typical turnaround |
|---|---|---|
| Fee proposal | From drawings and BCA report | Confirmed at scoping |
| Fire Engineering Brief | From accepted proposal and full drawings | Confirmed at scoping |
| Fire Engineering Report | From DFES advice on the FEB | Confirmed at scoping |
| Fire safety audit report | From site inspection | Confirmed at scoping |
| Design change assessment | From receipt of revised drawings | Confirmed at scoping |
Project scope
Fire engineering for the building and its approval pathway
The work required depends on the building, its design, its use and the relevant approval requirements. A proposal should set out the agreed scope, deliverables, assumptions and programme.
Where modelling or a Performance Solution is required, the basis and assumptions should be documented for project stakeholders.
Who we work with
Built around the people who deliver buildings
- Architects & designersEarly advice on fire safety objectives and project design options.
- Builders & contractorsAdvice on the fire safety implications of design changes and departures during construction.
- DevelopersFire engineering support for project design, assessment and approvals.
- Building owners & managersAudits and upgrade plans for buildings already in use.
- Building surveyorsFire Engineering Briefs and Fire Engineering Reports that document the project-specific assessment.
- Government & institutionsHealth, education, justice and infrastructure projects.
Know your stage? Send us the drawings.
Tell us about the building and attach your BCA report. We'll reply with a scoped, fixed-fee proposal.